Feature
Description of Change:
Silicon Labs is pleased to announce the following datasheet update: The CP2102N data sheet was updated from Revision 1.0 to Revision 1.1.
1. Updated the minimum Operating Supply Voltage on VDD to 3.0 V in 1. Feature List and Ordering Information, 3.1.1 Recommended Operating Conditions, 3.1.4 Configuration Memory, and Figure 2.3 Connection Diagram with Voltage Regulator Not Used on page 3.
2. Updated 4.3.6 Clock Output (CLK) to specify that the clock is not present when the device is in USB Suspend.
3. Updated QFN24 bottom pad label to GND instead of VSS.
4. Adjusted D, E, and aaa in QFN28 Package Dimensions.
5. Adjusted D, E, and L in QFN24 Package Dimensions.
Silicon Labs is also pleased to announce the following Errata update:
The CP2102N A01 errata includes the following errata for A01 revision. These issues will be solved in A01 devices with a date code of 1639 or later.
1. Systems using CP2102N may see devices fail to respond until a power-on reset. If a device fails to respond properly, remove and replace power until the device properly responds. Devices with a date code of 1639 or later will not have this issue.
2. CP2102N devices can fail to notify the host of an error flag if an error occurs while the host is reading the UART status. Devices with a date code of 1639 or later will not have this issue.
3. Devices may draw additional current on the order of normal operation mode when not connected to USB and in the self-powered configuration. The devices may not enter suspend mode properly if the USB host if disconnected. This issue is fixed in devices with a date code of 1639 or later.