Description
The TMP116 family (TMP116, TMP116N) consist of low-power, high-precision temperature sensors with integrated EEPROM memory. The TMP116 provides a 16-bit temperature result with a resolution of 0.0078°C and an accuracy of up to ±0.2°C with no calibration. The TMP116 is compatible with the I 2Cand SMBus interface, has programmable alert functionality, and supports up to four devices on a single bus.
The TMP116 consumes minimal current that, in addition to providing power savings, minimizes selfheating and improves measurement accuracy. The TMP116 operates from 1.9 V to 5.5 V and typically consumes 3.5 µA. Across the device operating temperature range of –55°C to +125°C, the TMP116 exceeds the accuracy of a class A RTD, while consuming less than one fifth
of the typical excitation current for a PT100 RTD.
The TMP116 is easier to use than RTDs, eliminating the need for calibration, external circuitry, matched traces, and Kelvin connections. The TMP116 units are 100% tested on a production setup that is NIST traceable and verified with equipment that is calibrated to ISO/IEC 17025 accredited standards
Features
• TMP116 accuracy without calibration:
– ±0.2°C (maximum) from –10°C to +85°C
– ±0.25°C (maximum) from –40°C to +105°C
– ±0.3°C (maximum) from +105°C to +125°C
• TMP116N accuracy, no calibration needed:
– ±0.3°C (maximum) from –25°C to +85°C
– ±0.4°C (maximum) from –40°C to +125°C
• Low Quiescent Current:
– 3.5-μA, 1-Hz conversion cycle
– 250-nA shutdown current
• Supply range: 1.9 V to 5.5 V
• Resolution: 16 bits at 0.0078°C (1 LSB)
• Programmable temperature alert limits
• Selectable averaging
• General-purpose EEPROM: 64 bits
• NIST traceability
• SMBus™, I2C interface compatibility
Applications
• Medical grade: meets ASTM and ISO spec
• Environmental monitoring and thermostats
• Wearables
• Asset tracking and cold chain
• Gas meters and heat meters
• Test and measurement
• RTDs replacement: PT100, PT500, PT1000
• Cold-junction compensation of thermocouples
(Picture: Pinout)