Ultra Small size x 1.0" For 1U Applications 60W convection cooled Universal Input 90-264Vac Approved IEC60601-1, 3rd Edition with 2 MOPP Level V Efficiency Compliant Models Less than 0.5W no-load Power Consumption 3 Year Warranty Optional LED indicator for power-on RoHS Compliant
DescriptionThe MB60S Series models provide a reliable power source in high power density x 1.0" package. Fully compliant to the applicable safety and EMC standards, these models will allow easy integration into many Medical applications. All 6 models are CE marked to low voltage directive and approved to Medical standards IEC60601-1 3rd edition with 2 MOPP.
Ripple & Noise* 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 360mV pk-pk 480mV pk-pkAt -20C, the noise and ripple 2% of the output. For product availability, please contact the factory
PARAMETER AC Input Voltage: AC Input Frequency: AC Input Current: Turn-on Input Voltage: Turn-off Input Voltage: Inrush Current:
Leakage Current (Input�Earth): Leakage Current (Output�Earth): Leakage Current (Input-Output): Input Fuses: Efficiency MB60S48K No Load Input Power: Turn-on Time: Hold-up Time: 60 Hz input, NC N/A 60 Hz input, 4A, 250VAC Typical <0.5W <2 Seconds 120Vac. 16mS minimum from loss of ac input at 120 Vac, full load. 24V, 36V, and 48V Models meet Level V requirement Meet Level V, standby Power Consumption 55 Watts for 12V output Fuses provided on all models Measured at 120Vac and full load IEC � 8.7.3.c
PARAMETER Output Power: Cooling: Total Regulation: Overload Protection: Short Circuit Protection: Overvoltage Protection: Overtemperature Protection: Minimum Load: Ripple and Noise: SPECIFICATION 60W continuous for operation from to 50�C55 Watts for 12V output. Convection �2% for all models 180% of rated output current value, Hiccup Mode Short across the output terminals will not cause damage to the unit. Hiccup Mode OVP firing reduces output voltage <50% of nominal in <50mS. See chart for trip range Automatic Power Shutdown 155�C, No minimum load is required 0.5% RMS, 1% pk-pk for all models. 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals, and load terminated with 0.1�F ceramic and 10�F low ESR capacitors Total regulation is the maximum deviation from nominal voltage for all loading conditions NOTES
500�s typ. response time for return to within 0.5% of final value for a 50% load change, i/t< 0.2A/�s. Max. voltage deviation 3.5%. 5% overshoot at turn-on, 5% overshoot at turn-off, under all conditions.
PARAMETER Insulation Safety Rating: CONDITIONS Input to Ground Input to Output to Ground Input to Ground Electric Strength Test Voltage: Input to Output to Ground Rating 2 MOPP 1 MOPP 1 MOPP 4000Vac 500Vac. NOTES
PARAMETER Operating Temperature: Temperature Derating: Cooling: Storage Temperature: Altitude: Relative Humidity: Shock: Vibration: SPECIFICATION to +80�C For 24V output and over, derate output power 60C, 40 Watt @ 70C, and 20 Watts for 80C Convection to +85�C Operating: to 3,000 meter Non-operating: to 40,000 ft. to 95%, non-condensing Non-Operating: Half-sine, 40 gpk, 10mS, 3 axes, 6 shocks total Random vibration per MIL-STD-810E, Method 514.4, Cat. 1, Figure hr in each of three axes NOTES -40� C Startup guaranteed <24V will derate at 70C, and at 80C
PARAMETER MTBF: Warranty: HALT Data: SPECIFICATION 700,000 hours, 25� C ambient, full load 3 Years Per SL Power Halt procedure NOTES Calculation is done based on Telcordia. Reports for each model is available Limited Report is available